Drager Gas Detector Manual



  1. Gas detection indoors: how to use sampling pumps: This document discusses the Draeger or Drager gas testing pump and gas detection tubes as tools and methods used to test for the level of toxic and other gases in buildings and in outdoors.
  2. DRAEGER MULTI-GAS MONITORS GAS DETECTION CATALOG THE MINIWARN MONITOR IS A MULTIPLE GAS-MEASURING DEVICE THAT IS WELL SUITED TO A WIDE VARIETY OF INDUSTRIAL GAS DETECTION APPLICATIONS. THE FLEXIBILITY OF THE MINIWARN PRODUCT LINE ALLOWS EVERY USER TO OPTIMALLY CONFIGURE AN INSTRUMENT TO MEET THEIR NEEDS.
  3. Portable Gas Detection With 70 years of experience, our portable gas detectors offer precise, reliable and multifunctional measurement of harmful gases. The portable gas detectors are used for diverse applications like personal workplace monitoring, clearance measurement of confined spaces, leakage detection, area monitoring and many more.

Draeger Multi Gas Detector Manual

Automated gas detector test systems maintain calibration and track data for a compatible gas detector. Calibration gas is used for testing the sensitivity of gas detectors. Gas-detection control panels manage multiple gas sensors, communicate the status of a detection system,. Looking for DRAEGER Multi-Gas Detector, 5 Gas (36E621)? Grainger's got your back. Easy online ordering for the ones who get it done along with 24/7 customer service, free technical support &.

Manual

Dräger Gas Detection Tubes

Since Draeger introduced their first gas detections tubes in 1937, they have remained the leader in industrial gas and vapor analysis. Since then, they have developed more detection devices and tubes for more applications than any other detection company. Draeger's game changing technology has helped them retain leadership in colorimetric detector tubes providing the most accurate results available on the market today.
  • Draeger Tubes can be delivered to most locations in continental North America within 24 hours.
  • Accurate
  • Easy to Read / Easy to Use
  • Fast
  • Flexible
  • Specific

Dräger Accuro® Pumps

Draeger has made gas detection easy. Unlike a piston pump, the accuro pump requires no lubrication. The accuro® is constructed of non-metalic, corrosion resistant materials. It can't be bent by rough treatment and it withstands harsh chemical environments. Drager Gas Detector Manual
  • Accurate
  • Fast
  • Factory Calibrated
  • Maintenance Free

Dräger X-act 5000

The automatic tube pump Dräger X-act 5000 is the first all-in-one solution designed for measurements with Dräger short-term tubes and for sampling tubes and systems. Ease of operation and a high degree of reliability compliment the measurement and sampling of gases, vapors and aerosols. Detector
  • New Pump Concept
  • Simplicity of Operation
  • Automatic Transfer of Measurment Parameters
  • Measurement in Technical Gases
  • Direct Settings for Sampling

Dräger Chip Measurement System (CMS)

The CMS combines substance specific measuring Chips with an electronic based Analyzer for an easy to use spot-measurement system. The 10 capillaries in each Chip are filled with a reagent system based on Draeger's 60+ years of colorimetric chemistry expertise. The analyzer combines a revolutionary optical system for analyzing the color reaction with a mass flow controller and pump system that provides unbeatable reproducibility.
  • Fast Response Time
  • Unequaled Accuracy
  • Chemical Specific Measurements
  • Simplified Operation and Maintenance
  • Data Recorder

Drager Gas Detector Pdf

The Dräger Polytron® 7000 is a gas detector that can satisfy many toxic and oxygen gas measurement applications on a single platform. It meets the requirements of the compliance market as well as the high specification requirements of customised solutions.

Specifications

Dräger developed the simple and structured software menu of the Polytron 7000 in collaboration with its customers. The big graphic display shows status information with the help of icons and plain text, and guides the user through calibration and configuration.

The wide range of outputs, 4 to 20 mA, HART®, LON, PROFIBUS® or FOUNDATION Fieldbus™, enables the use of the Polytron 7000 on either a control system from the Dräger Regard family, or third party control systems. The modular design allows for the subsequent retrofit onto any of the mentioned interfaces.

Draeger gas detector

With the Polytron 7000 remote sensor adaptor and lead it is possible to mount the sensor up to 30 metres from the polytron 7000 transmitter. This enables the user to read and operate the transmitter from a safe area, or detect toxic gasses and oxygen levels in difficult to reach areas, whilst still being able to view and configure the Polytron 7000 from a convenient location. A duct mount kit enables the remote sensor to be mounted direct in elevated pipe work.

The Dräger Polytron 7000 can be equipped with a relay module. With two gas alarm relays, and one fault alarm relay, the transmitter can either be used as a stand alone gas detector with no need for a controller; or alarm devices can be activated locally saving costs in cabling to and from a controller. The analogue signal can still be transmitted back to a controller if desired. (Not suitable for use in hazardous areas)

Drager Gas Detector Manual

The Dräger Polytron 7000 can detect over 100 different gases. DrägerSensors are specifically designed for the demands of 24 hours per day, 365 days per year operation. The large DrägerSensor size gives them their renowned long life. The built-in sensor data memory containing all the relevant gas and calibration information, together with on board temperature and pressure compensation gives the DrägerSensor its unsurpassed measurement performance. This also allows the Polytron 7000 to accept pre-calibrated sensors, with minimal operator intervention, the Dräger Polytron 7000 is a virtually maintenance free transmitter.

With three different software dongles, a range of functions are incorporated into the transmitter adjusting it to user or application specific requirements.With the sensor test dongle, the Dräger Polytron 7000 performs many different patented sensor tests that ensure the reliability and functionality of the sensor and gas detection system. With the new sensor diagnosis function (including the sensor test), operational demands and the remaining sensor life time is estimated so that maintenance and exchange schedules can be created. A data and event saving option is integrated into the data dongle. This saves the measured values and events such as alarms and warnings. The data can be downloaded onto a PDA m515-Ex via an IR interface and evaluated on a PC with the Dräger GasVision softwareor at the push of a button, a 15 minute concentration history is shown on the transmitter display.

The inclusion of a pump module enables the Polytron 7000 to draw gas samples from difficult to reach areas, the gas sample is then passed across the DrägerSensor for detection. The pump unit, like all accessories in the Polytron 7000 range is modular, and can be retrofitted into existing transmitters. (Not suitable for use in hazardous areas)